Introduction

 

Sequence

System diagnosis
   
 

 

System diagnosis
CONDITION CAUSE REMEDY
A.Pump does’t operate 1.Insufficient air supply
2.Timer control failing to operate solenoid shut-off.
3.Lubricant has hardened in drum.
1.Adjust air pressure to 40/50Psi.If condition persist,increase air pressure to pump
2.Check wiring of system timer according to instructions and SS4500 controller. Also check timer for proper programming
3.Use smaller sized drums-diluent in some lubricants tends to evaporate causing lubricant to harden.

B. Pump operates but doesn’t build pressure.

1.Reservoir empty
2.Broken line
3.Air in system
1.Check and renew lubricant supply .Purge air from lines
2.Repair or replace as necessary.
3.Bleed lines and valves as described on web

C.Manifold valve indicator doesn’t operate

1.Lack of pressure
2.Valve manifold is blocked
3.Plugged discharge line
1.Repair-see condition B
2.Replace
3.Locate obstruction,remove line and blow clean ,or replace faulty section